GE Energy
WattStation
TM
Wall Mount: Installation Guide
Plug-in Version
imagination at work
Before Installation:
WattStation should be installed only by a licensed
contractor, and/or a licensed electrician in accor-
dance with all applicable state, local and national
electrical codes and standards.
• Ensurethatadedicatedcircuit,capableofsupplying
30Aat208-240VAC,isavailable
• Powerfeedmusthaveacentrallygroundedneutralin
orderforWattStationtofunctioncorrectly.
• WallreceptaclemustbeaNEMA6-50outlet.
Arecommended40Aupstreamcircuitbreaker,located
eitherinapanelboardorloadcenter,shouldbeused
• Distancebetweenthewallpowerreceptacleand
WattStationmountingshouldbelessthanone(1)foot
• Wallpowerreceptaclewithaweatherprooflockingcover
isrequired
• Recommendedmountinghardwareforwoodstudsare
3/8”x2”hexheadlagbolts
• Recommendedmountinghardwareforconcretewalls
are3/8”x1-3/4”concretehexscrewsor3/8”x1-7/8”
concreteanchors
Installation Instructions:
Step 1: Carefullyunwrapthepackagingandmakesure
thefollowingitemsarepresent:
- WallMountedWattStationunit
- Mountingwallbracket
- Templateforwall-mountingholes
- KeyforWattStationmountinglock
(storedinsideWattStationunit)
Step 2: Checkforanydamagetotheunit,thecordorthe
connector.Ifnodamageisnoticed,proceedtostep3.If
damageisnoticed,call1-888-GE-RESOLve.
Step 3: Installwallmountbrackettothewall.Usethe
providedtemplatetolocatewall-mountingholestoensure
holelocationsmatchthebracket.Distancefromoorto
bottomofwallmountbracketshouldbe18”minimumfor
indooruseand24”minimumforoutdooruse.Distancetothe
topoftheunitshouldbe48”maximumforallapplications
perNEC625.29.ForADAcompliantinstallation,refertoADA
accessibilityguidelines,section4.2.
STEP (3 PI & HW)
WARNING: Danger of electrical shock or injury. Turn
OFF power at the panelboard or load center before
working inside the equipment or removing any
component. Do not remove circuit protective devices or
any other component until the power is turned OFF.