GE Z-Wave 45606 - Detailed Parameter Settings; Dim Command and Manual Control Parameters; Start Level Ignore Parameter

GE Z-Wave 45606
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1. When Receiving a Z-Wave Dim Command
- Parameter 7 (number of steps or levels)
- Parameter 8 (timing of the steps)
- Length: 1 Byte
Valid Values:
Parameter 7 (default = 1) Valid Values: 1-99
Parameter 8 (default = 3) Valid Values: 1-255
2. Manual Control Dimming (pressing the Dimmers rocker)
- Parameter 9 (number of steps or levels)
- Parameter 10 (timing of the steps)
- Length: 1 Byte
Valid Values:
Parameter 9 (default = 1) Valid Values: 1-99
Parameter 10 (default = 3) Valid Values: 1-255
3. When Receiving an All-On or All-Off Command
- Parameter 11 (number of steps or levels)
- Parameter 12 (timing of the steps)
- Length: 1 Byte
Valid Values:
Parameter 11 (default = 1) Valid Values: 1-99
Parameter 12 (default = 3) Valid Values: 1-255
Ignore Start Level When Receiving Dim Commands
Please note: Every Dim command includes a start level
embedded in it.
The 45606 can be set to ignore the start level that is part of the
dim command. Setting parameter 5 to a value of 0 will cause the
45606 to dim or brighten from the start level embedded in the
command.
- Parameter No: 5
- Length: 1 Byte
- Valid Values = 0 or 1 (default 1)