ZP3 Fire Control Panel User Guide
Main operating controls
See Figure 7. Five controls are used to operate the system as follows:
Figure 7: Main operating controls
ACCEPT
MUTE
BUZZER
RESET FIRE FAULT DISABLED OTHER
SILENCE
ALARMS
SOUND
ALARMS
DISABLED DELAYED PRE-ALM TEST ENABLE
CONTROL
ON
OFF
FAU LTAC TIVEPOWER ON
SYSTEMNIGHT
ZONEDAY
POINTMORE TIME
SOUNDER S
REMOTE ALARM
CONTROL OUTPUTS
RESTORE
DISABLED
ALARMS
3690
-
0
1
Si
l
ence A
l
arms
Button
Sound Alarms
Button
Reset
Button
Accept
Mute
Buzzer
Restore Disabled
Alarms Button
Optional
Day/Night
Module
Accept button
Press the Accept button after receipt of an alarm. This causes the illuminated indicators to go
steady, and silences the panel buzzer.
Reset button
Press the Reset button to clear all alarms from the system and restore the panel to a normal “no-
alarm” condition.
All displayed alarms are removed, and all illuminated indicators are switched off. Sounders
(unless programmed dynamic) are switched off, and the remote manned centre alarm is restored
to a "no-alarm" condition. If any sensors, call points, or other devices still sense fire, smoke or a
fault, then the panel returns to an alarm condition.
Silence alarms button
Press the Silence Alarms button to silence (switch-off) the sounders.
An alarm condition activates certain sounders throughout the building. Which sounders are
activated depends on the configuration of your system. After pressing the Silence Alarms button,
the Sounders Silenced indicator above the button illuminates.
Sound alarms button
Press the Sound Alarms button to activate all the sounders in the building.
This can be done, for example, to sound a general alert or to restore sounders that were silenced.
Restore disabled alarms button
In Software version 3.10 and earlier: Press the Restore Disabled Alarms button to restore
disabled sounders.
In Software version 3.11 onwards: Press the Restore Disabled Alarms Button to toggle between
Disable All Sounders and Enable All Sounders, as indicated by the Sounders Disabled LED.
Maintenance Staff can disable alarm sounders for routine maintenance. If a fire alarm occurred
while these devices were disabled, the sounders wouldn't work. Pressing the Restore Disabled
Alarms button to enter the Enable All Sounders state also cancels (overrides) any programmed
delays and creates an immediate alarm. Pressing this button doesn’t create an alarm, but simply
restores alarm devices to allow them to operate correctly during an alarm.