SAE/ISO Operating Controls Selector Valve
Located on the lower left side of the chassis, under the
cab, is the SAE/ISO Selector Valve. See (1), Figure 3-
13. The SAE/ISO valve can be accessed through a cut-
out on the left side of the chassis at location (2). This
machine has been set at the factory for SAE standard
operation shown at position (3). If ISO operation is
desired, loosen wing nut (5) and rotate valve to position
(4) and retighten wing nut (5).
Figure 3-13 SAE/ISO Selector Valve
CAUTION
Check tilt rod (9), the retention pin and
safety cable (8) at regular intervals for
cracks and cuts. Replace defective parts
immediately.