EasyManua.ls Logo

Gehl R135 - Checks During Operation

Gehl R135
206 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
82 50940193/DP0415
Checks During Operation
Complete the following checks after starting the engine and during operation.
Overall machine condition (including
attachments) for bends, cracks, broken, loose or
missing parts, etc.
Engine cover securely closed and latched?
Rags, tools, debris and other loose objects
removed? (check especially after maintenance)
Approved warning triangle, hazard warning light
and first aid kit in the machine?
Perform safety interlock system test See “Safety Interlock System Test” on page 42.
Seat position correctly adjusted? “Operator’s Seat” on page 39.
Seat belt fastened? “Seat Belt” on page 40.
Table 12: Checks During Operation
Check Refer To:
After Starting the Engine/During Operation
Engine oil pressure and charge indicator lights
not on?
“Control Keypad” on page 48.
Parking brake released after starting engine and
before operating machine?
Coolant temperature indicator light not on? “Control Keypad” on page 48.
Perform restraint bar safety interlock system
test.
See “Restraint Bar Test” on page 42.
Steering operating properly? “Controls” on page 59.
Engine exhaust excessively smoky?
Anyone hazardously close to the machine?
When Driving on Public Roads
Attachments in transport position? “Attachment Transport Position” on page 94.
Table 11: Pre-Start Checks
Check Refer To:

Table of Contents

Related product manuals