RS5-34 Telescopic Handler HYDRAULIC PUMP
MANDATORY SAFETY SHUTDOWN
PROCEDURE
BEFORE cleaning, lubricating, or servicing this
equipment:
1. Bring the machine to a full stop on a level
surface. (If parking on a slope or hillside cannot
be avoided, park across the slope and block the
tires.)
2. Fully retract the boom and lower the attachment
to the ground.
3. Place controls in NEUTRAL and set the park
brake.
4. Idle the engine for gradual cooling.
5. Turn the keyswitch to OFF position and remove
the key. (Take the key with you for security
reasons.)
ONLY when you have taken these precautions can
you be sure it is safe to proceed. Failure to follow the
above procedure could lead to death or serious
injury.
HYDRAULIC PUMP REMOVAL
STEP 1
G0805075
Loosen the two thumbscrews (1) and remove the
battery access cover (2).
STEP 2
G0905077
Remove the four screws (1) and the fuel filter access
cover (2).
STEP 3
G0905079
Remove the five bolts and the transmission cover.
1
1
2
1
1 1
1
2