RS5-34 Telescopic Handler ELECTRICAL
INSTRUMENT PANEL OR PANEL BULB REPLACEMENT
STEP 1
G0805159
Turn the key switch off. Remove the key.
STEP 2
G0805182
Remove the six screws securing the instrument
panel.
STEP 3
G0805142
Pull the instrument panel out from the dash. mark the
position of all wires and connectors on the instrument
panel for reassembly. Remove the wires and
connectors.
STEP 4
G0805144
To remove the instrument panel bulbs, rotate the
bulbs 1/4 turn counterclockwise.
STEP 5
Install the new bulbs and rotate 1/4 turn clockwise to
lock into the instrument panel. Reconnect the switch
and gauge connectors.