25. Procedures for Maintenance
3-51
25-6-4. Adjusting the governor lever and accelerator devices
The governor lever and the accelerator devices (i.e., accel-
erator lever, pedal.) are connected by an accelerator wire.
If the wire becomes stretched or if the connections loose,
deviation in position may result and make operation un-
safe. Inspect the wire periodically and adjust if necessary.
1) Check that the governor lever on the engine side is
touching the restraint bolt on the high speed side when
the accelerator device is in the high speed position.
2) Check that the governor lever on the engine side is
touching the restraint bolt on the low speed side when
the accelerator device is in the low speed position.
3) If the governor lever does not touch the restraint bolt on
either the high or low speed side when you check them,
loosen the setting screws on the fittings for the acceler-
ator wire and adjust the position of the wire.
Perform the same maintenance as indicated for every 50 service hours.
Never remove the restraint bolt for the fuel injec-
tion pump or the restraint bolt governing the
amount of fuel injected. Doing so will impair safe
operation, lower the efficiency of the engine and
shorten its life.
25-7. Maintenance every 250 service hours
High speed restraint bolt
Governor lever
Low speed
restraint
bolt
Wire fittings
High speed
Low speed
Accelerator wire