12. Description of Control Devices
2-16
The following two types of fuses are used in the
electrical wiring circuit :
Blade fuse
• Protect the electrical equipment from overcurrent which
exceeds the allowable limit of the electrical equipment.
• Protect the wiring from overcurrent which exceeds the
allowable limit of the wiring due to a problem with the
electrical equipment.
Slow-blow fuse
• Protect the electrical equipment and the wiring from a
burnout caused by overcurrent which flows in the circuit
for large-capacity current when a problem occurs (such
as short-circuit due to breaking of wire).
Position of the fuse box
Fuse box is on the right front of the seat mount.
12-7. Fuse
• When replacing a fuse, be sure to turn off the
power by turning the starter switch key to the
OFF position.
• Using the wrong fuse or shorting out a fuse hold-
er could damage the gauges, the electrical equip-
ment and the wiring due to overheating.
• If a new fuse blows out immediately after re-
placement, there may be a problem with the elec-
trical system. Ask your dealer for assistance.
020318-00E
Open
Cover
Slow-blow fuse
Blade fuse