13. Operating Instructions
2-27
13-1-3. Operating and checking instructions before
starting up the engine
1) Check that the lock levers (1) are in the lock position.
2) Check that all other levers are in their appropriate posi-
tions.
3) Fasten the seatbelt snugly.
4) Insert the starter switch key into the starter switch (2) and
set it to the "ON" position. Then check the following points:
[1] The buzzer will sound, and the following alarm lamps
will go on.
Engine oil pressure alarm lamp (3)
Battery charge alarm lamp (4)
Water temperature alarm lamp (5)
(It goes off in 2 to 3 seconds)
If any of the alarm lamps do not go on or the buzzer does
not sound, it may mean that an alarm lamp has blown out
or is broken. Take corrective action, or consult your dealer
for assistance.
[2] Turn the light switch "ON" to see whether the boom
light will go on. If it does not go on, the lamp might have
blown out or might be broken. Take corrective action, or
consult your dealer for assistance.
Accidentally operating a control lever can cause
the machine to move suddenly, possibly causing
a serious accident.
When leaving the operator's seat, be sure to
place the lock levers securely in the lock posi-
tion.
(1)
(1)
(2)
020339-00X
Lock
(Left side)
Lock lever
020323-00E
000392-00X
(4)
(3)
(5)
ON
OFF
000328-00X
Courtesy of Machine.Market