IMPORTANT
The proper hydraulic oil temperature is between
122°F and 17F (50°C and 80°C).
If you have to operate the machine at a low hydraulic
oil temperature, increase the hydraulic oil temperature
to about 68°F (20°C) before operating the implement.
In the event that you have to operate any control le-
ver at a temperature lower than 68°F (20°C), operate
it gently.
Do not accelerate the engine rapidly until the engine
warms up.
After starting the engine, do not start operating the ma-
chine immediately but follow this procedure:
1) Idle the engine, to check that the engine oil pressure
alarm lamp is off.
2) Pull the accelerator lever (1) to the midpoint between
the "IDLING" and "RUN" positions, and run the engine
with no load at medium speed for approximately five
minutes.
13-3. Operating and checking instructions after starting the engine
Emergency stop.
If abnormal operation occurs, turn the starter
switch key to the "OFF" position, to shut off the
electrical system and the engine. Then ask your
dealer to check the machine.
Be sure to warm up the engine. If you operate the
implement without full warm-up, the machine
may not respond or operate properly, especially
in cold weather.
020327-00X
(1)
000321-00X
020325-00E
Idling
Run
(1)
Courtesy of Machine.Market