17. Troubleshooting
2-94
17-3-1. Starting the engine using booster cables
To start the engine using booster battery cables, do the fol-
lowing.
Precautions for connecting and disconnecting the
booster cables
IMPORTANT
The booster battery cables capacity and the clip size
should be suitable for the battery size.
The battery of the normal machine should be the
same capacity as that of the machine in trouble.
Check the booster battery cables and clips for an ab-
sence of damage, cracks, and corrosion.
Securely connect the clips.
When you start the engine using booster cables,
wear safety goggles.
If you start the engine by taking electric power
from another machine, do not allow contact be-
tween your machine and the other machine.
To connect the booster cables, begin with the
positive terminal, and to disconnect them, begin
with the negative terminal (ground side).
If a tool touches the positive terminal and the ma-
chine at the same time, hazardous sparks may be
generated.
Do not connect the booster cables to terminals
of reverse polarity. That is, never connect a neg-
ative terminal on one machine to the positive ter-
minal on the other machine.
As the last step, connect the negative booster
cable to the upperstructure. At this time, sparks
will be generated. Connect the terminal to a point
as far away from the battery as possible.
000518-00X