V 12/13
OptiMove CR07 Axes operating modes 37
Setup
If an object is hanging in the booth, it is very advantageous if the upper
and lower reversing point (or travel positions in sequence programs) can
be directly taken from the object to be coated in a Teach-In procedure.
The program parameters of the present program can be set, and the axis
travels with this modification. It is also possible to select the program
number.
Setup mode by keyboard (pendulum operating
mode / semiautomatic mode)
1. Press the and key at the same time.
The corresponding LED blinks
2. Press
in the display area A1, in order to start the axis
- LED 1 blinks
- Axis travels to the upper reversing point
3. Adjust the upper reversing point on display A1 using the keys
- Axis travels with the modification
- The position of the upper reversing point is programmed
4. Press
in the display area A2 in order to start the axis
- LED 2 blinks
- Axis travels to the lower reversing point
5. Adjust the lower reversing point on display A2 using the keys
- Axis travels with the modification
- The position of the lower reversing point is programmed
6. Select the desired program number using
keys. The
display A3 shows the program number
7. Press the
key, in order to exit the setup mode
Setup mode by keyboard (sequence program)
1. Press the and key at the same time.
The corresponding LED blinks
2. Press
in the display area A1, in order to start the axis
- The axis travels to the position of the first program step
3. On the display A1, adjust the positions using the
keys
- LED 1 blinks
- Axis travels with the modification
- The position of the first program step is programmed