V 12/13
38 • Axes operating modes OptiMove CR07
4. Press to select the next program step
- Display A3 shows - - -
5. Select the desired program number using
keys. The
display A3 shows the program number
6. Repeat the steps 2-5 for further programs
7. Press the
key, in order to exit the setup mode
RAM reset
In the RAM reset mode, all preset values and system parameters are
loaded with default values.
Entering the RAM reset mode
1. Switch off the axis control unit by pressing
2. Keep pressed the
key, and at the same time switch on the
axis control unit with
. Keep pressed the key for further 10
seconds.
The value 255 appears on the display A3, and the LED L3 blinks.
All other displays remain dark
3. Press the
key, in order to exit the RAM reset mode
Default values after RAM reset
Name Default value
Preset values
Upper position (m)
0.30
Lower position (m)
0.00
Speed upwards [m/s]
0.20
Speed downwards [m/s]
0.20
System parameters
P1 - Upper stroke limit (also applied as travel position
for horizontal axis)
0.30
P2 - Operating mode
1
P3 - Acceleration [m/s
2
]
1.50
P4 - Max. speed [m/s]
0.60