Product description OptiStar 4.0 (CG24-CP)
Pneumatic data
OptiStar
Compressed air connection
Quick coupling
Inlet pressure
6.0 bar
Max. input pressure
10 bar / 145 psi
Min. input pressure (while unit in
operation)
6.5 bar / 95 psi
Max. water vapor content of the
compressed air
1.3 g/m³
Max. oil vapor content of the
compressed air
0.1 mg/m³
Dimensions
OptiStar
Width
173 mm
Depth
250 mm
Height
177 mm
Weight
approx. 2.6 kg
Powder output (reference values)
General conditions for the Application pump
Powder type
Epoxy/polyester
Length of powder hose (m)
20
Powder hose Ø (mm)
7
Type of powder hose
POE with guide strips
Input pressure (bar)
6.0
Correction value C0
9
Air flow rates
The total air consists of transport air and supplementary air, in relation to
the selected powder quantity (in %). As a result the total air volume is
maintained constant.
OptiStar
Transport air flow rate
0-3.5 Nm³/h
Spraying air flow rate
0-4.5 Nm³/h
Electrode rinsing air flow rate
0-3.0 Nm³/h
The total air consumption for the device is determined based on
the configured air values.