Rev. 00 03/19
42
Operation OptiStar 4.0 (CG24-CP)
Starting the individual adjustable programs
1. Turn on the gun control unit with the ON key
2. Press the program key
3. Select desired program (001-250 / 01-20)
4. Change the coating parameters as required
Programs 001-250 (01-20) are preset at the factory but can be
modified at any time, after which they are automatically stored.
Setting powder output and powder cloud
The powder output depends on the selected powder output (in %), and
the powder cloud on the selected total air volume.
The AP01 Application pump should be operated with powder at
least 1/2 hour after starting up.
– After the running-in of the filter elements a stable powder output
value will be reached.
As a factory default value, a powder rate of 60% and a total air
volume of 4 Nm³/h are recommended.
– If values are entered that the gun control unit cannot implement,
then the operator is informed of this by a blinking in the relevant
display and a temporary error message!
Setting the total air volume
1.
Adjust the total air volume on the gun control unit with the T3/T4
keys
– Adjust the total air volume according to the corresponding coating
requests