Operation OptiStar 4.0 (CG24-CP)
Starting the individual adjustable programs
1. Turn on the gun control unit with the ON key
2. Press the program key
3. Select desired program (001-250 / 01-20)
Program 250 active
4. Change the coating parameters as required
Programs 001-250 (01-20) are preset at the factory but can be
modified at any time, after which they are automatically stored.
Description
Presetting
Powder output
60 %
Total air
4.0 Nm³/h
High voltage
80 kV
Spray current
20 µA
Electrode rinsing air
0.1 Nm³/h
Setting powder output and powder cloud
The powder output depends on the selected powder output (in %), and
the powder cloud on the selected total air volume.
The AP01 Application pump should be operated with powder at
least 1/2 hour after starting up.
After the running-in of the filter elements a stable powder output
value will be reached.
As a factory default value, a powder rate of 60% and a total air
volume of 4 Nm³/h are recommended.
If values are entered that the gun control unit cannot implement,
then the operator is informed of this by a blinking in the relevant
display and a temporary error message!
Setting the total air volume
1.
Adjust the total air volume on the gun control unit with the T3/T4
keys
Adjust the total air volume according to the corresponding coating
requests