V 02/18
30 Initial start-up OptiStar CG08(-C)
System parameter P10
The device can export log reports of the program run to an SD card for
test purposes and for finding defects.
If an SD card is inserted during the switching on procedure, the log
messages are also recorded onto the SD card. The data are record in the
MESSAGES.LOG file in the root directory. Once this file reaches a size
of 32 MB, it is renamed as MESSAGES.1 and a new MESSAGES.LOG
file is then created.
Parameter value Level of detail of reports
0 no messages
1 few details
...
5 all messages
NOTE:
Real time timings can be impaired from a level of detail of 4.