EasyManua.ls Logo

Genelec 7040A - System and Amplifier Specifications; System Specifications; Amplifier Section; Crossover Section

Genelec 7040A
6 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7040A Operating Manual
Genelec Document D0126R001a Copyright Genelec Oy 9.2016. All data subject to change without prior notice
www.genelec.com
International enquiries:
Genelec, Olvitie 5
FIN-74100, Iisalmi, Finland
Phone +358 17 83881
Fax +358 17 812 267
Email genelec@genelec.com
In the U.S. please contact:
Genelec, Inc., 7 Tech Circle
Natick, MA 01760, USA
Phone +1 508 652 0900
Fax +1 508 652 0909
Email genelec.usa@genelec.com
In China please contact:
Beijing Genelec Audio Co.Ltd
Room 101, 1st oor, Building 71 B33
Universal Business Park, No. 10 Jiuxianqiao Road
Chaoyang District, Beijing, China
Phone +86 (10) 5823 2014
Post code: 100015
Email genelec.china@genelec.com
AMPLIFIER SECTION
INPUT SECTION
CROSSOVER SECTION
SYSTEM SPECIFICATIONS
7040A
Free eld frequency response (-6 dB) 30...90 Hz
Accuracy of frequency response ± 3 dB (33...85 Hz)
Maximum short term sine wave SPL output
averaged from 40 to 85 Hz, measured in half
space at 1 meter
100 dB
Self generated noise level in half space at
1 m (A-weighted)
≤ 5 dB
Harmonic distortion at 90 dB SPL
at 1 m on axis in half space 40…85 Hz
2nd
3rd
≤ 2.5%
≤ 1.5 %
Driver, magnetically shielded 165 mm (6
1
/2 in)
Weight 11.3 kg (24.9 lb)
Dimensions
Height
Width
Depth
410 mm (16
1
/8 in)
350 mm (13
3
/4 in)
205 mm (8
1
/16 in)
OUTPUT SECTION
7040A
Subsonic lter (18 dB/octave) below 35 Hz
Input channels 2
High pass frequency for main channel
outputs
85 Hz
Midband rejection >400 Hz ≥ 50 dB
Bass Roll-O control in 2 dB steps 0 to -6 dB @ 35 Hz
Phase matching control in 90° steps 0 to -270°
Input sensitivity control +12 to -6 dBu
7040A
Amplier short term output power
(Long term output power is limited by driver
unit protection circuitry)
50 W
Amplier system THD at nominal output ≤ 0.08 %
Mains voltage 100 - 240 VAC universal
Power consumption (average)
Standby (ISS active)
Idle
Full output
≤ 0.5 W
5 W
70 W
7040A
Input connectors XLR female
pin 1
pin 2
pin 3
gnd
+
-
Input impedance 10 kohm balanced
Input level for 100 dB SPL output @ 1 m Variable from +12 to -6
dBu
7040A
Input connectors XLR male
pin 1
pin 2
pin 3
gnd
+
-
Main monitor Out gain 0 dB