Section 3 • Scheduled Maintenance ProceduresJanuary 2012
Part No. 228901 GS-30 • GS-32 • GS-46 • GS-47 3 - 21
CHECKLIST B PROCEDURES
B-14
Check the Module Tray Latch
Components
Genie requires that this procedure be performed
every 250 hours or quarterly, whichever comes
first.
Maintaining the module tray latch components in
good condition is essential to good performance
and service life. Failure to detect worn out latch
components may result in module trays opening
unexpectedly, creating an unsafe operating
condition.
1 Inspect each module tray rotary latch and
related components for wear. Tighten any loose
fasteners.
2 Lubricate each module tray rotary latch. Using
light oil, apply a few drops to each of the
springs and to the sides of the rotary latch
mechanism.