Grease fire or continuous
excessive flames above
cooking surface
much grease buildup in burner area
Turn off LP Tank. Leave lid open to allow
flames to die down. After cooling, clean
food particles and excess grease from
inside firebox area, grease cup/pan/tray,
and other surfaces
Burner will not light using
ignitor
Burner not engaged with control valve
Coupling nut ad LP tank valve not
1. Make sure valve are positioned inside of
burner tubes.
2. Ensure burner tube is not obstructed
with spider webs or other material, see
cleaning section of use and care
3.Make sure LP tank is not empty. If LP
tank is not empty, refer to “sudden drop in
gas flow.
4. Turn the coupling nut approximately
one
Gas leaking from
cracked/cut/burned hose
Turn off gas at LP tank, if hose is cut or
cracked, replace hose.
Mechanical failure due to resting or
mishandling
Turn off LP tank valve and replace.
Gas leaking from LP tank
valve
Failure of tank valve from mishandling or
mechanical failure
Turn off LP tank valve and replace.
Gas leaking between LP tank
and regulator connection
Improper installation, connection not
tight, failure of rubber seal
Turn off LP tank valve, remove regulator
from cylinder and visually inspect rubber
seal for damage.
Fire coming through control
panel
Fire in burner tube section of burner due
to partial blockage
Turn off control knobs and LP tank valve.
After fire is out and grill is cold, remove
burner and inspect for spider nests or rust.