3. Power on the camera using the power cable or the PoE cable.
4. Hold the default button until the two network LEDs fade. This will take about 25 seconds.
Network LEDs
5. When default loading is completed, the camera will pan and tilt to its full range and return
to the home point.
Vandal Proof IP Dome
1. Keep the power and network cables (or PoE) connected to the camera.
2. Use a pin to press and hold the default button on the inner housing.
Status LED
Default button
3. Release the default button when the status LED blinks. This shall take about 8
seconds.
4. When the status LED fades, the process of loading default settings is completed and the
camera reboots automatically.