saddles
Type Description
2 to 4 in., cut 1-7/16 in. hole in pipe
Over 4 in., cut 2-1/4 in. hole in pipe
Special order over 12 in.
0.5 to 4 in. versions
PVC or CPVC
Mounts via glue-on fittings
Plastic tees
PVC glue-on
saddles
(O-ring not
required)
2 to 4 in., cut 1-7/16 in. hole in pipe
6 to 8 in., cut 2-1/4 in. hole in pipe
Align wedge arrows with saddle arrows during assembly.
Pipes over 8 in., use iron saddle
0.5 to 2 in. versions
Mounts on threaded pipe ends
Carbon steel
threaded tees
Carbon steel
weld-on
weldolets
2 to 4 in., cut 1-7/16 in. hole in pipe
Over 4 in., cut 2-1/4 in. hole in pipe
Remove insert before welding
Installed by certified welder only
Special order over 12 in.
Metric plastic saddle
For pipes DN 65 to 200 mm
Requires a 30 mm diam. hole in the pipe
Wedge and saddle arrows must match
Metric wafer fitting
For pipes DN 65 to 200 mm
Follow the recommended installation guidelines
Metric union fitting
For pipes from DN 15 to 50 mm
PP or PVDF
Follow the recommended installation guidelines
Type Description
3-2536.090-1
1. Location of Fitting
Recommended sensor upstream/
downstream mounting requirements.
2. Sensor Mounting Position
Horizontal pipe runs: Mount sensor in the upright (0°) position for best overall performance. Mount at a
maximum of 45° when air bubbles are present. Do not mount on the bottom of the pipe when sediments
are present.
Vertical pipe runs: Sensor must be mounted in lines with UPWARD flow only.
3. Sensor Wiring
+
GF
+
SIGNET 2536/3-8512-XX Low Flow Sensor
4.
+
GF
+
SIGNET Fittings
ENGLISH
SAFETY INSTRUCTIONS
1. Do not remove from pressurized lines.
2. Do not exceed maximum temperature/pressure specifications.
3. Do not install/service without following installation instructions (see sensor manual).
4. Wear safety goggles and faceshield during installation/service.
5. Do not alter product construction.
6. Failure to follow safety instructions could result in severe personal injury!
Use 2-conductor shielded cable for cable extensions up to
300 m (1000 ft).
Cable shield must be maintained through cable splice.
+
GF
+
SIGNET Intelek-Pro, use 2536 input card setting
Refer to you instrument manual for specific wiring details.
black (3.3 to 24 VDC)
red (signal out)
silver (DC return)
2536/3-8512-XX
Sensors
2536 Sensor
Input
Gnd.
10 k
+
3.3 to 24
VDC
-
black
silver
red
Pull-up resistor required (10 k recommended).
Use 2-conductor shielded cable for cable extensions up to
300 m (1000 ft).
Cable shield must be maintained through cable splice.
Other
instrument
Blk, Sensor
Power
Red,
Freq. input
Shld
Gnd
+
GF
+
SIGNET instrument
Other Brands
10x I.D. 5x I.D.
Inlet
Outlet
Flange
15x I.D. 5x I.D.
Reducer
20x I.D. 5x I.D.
90° Elbow
50x I.D. 5x I.D.
40x I.D. 5x I.D.
25x I.D. 5x I.D.
2 x 90° Elbow
2 x 90° Elbow