Password-protected menus Instruction manual
24
Press the button User Menu: Exit.
The new values are stored and the password-protected menu is closed.
10.3 Changing the selection menus
The procedure for changing the preset values is the same for all menus.
Open the password-protected menu.
See Section 10.2 Opening a password-protected menu, Page 23.
For example, select the Flow Units parameter.
The current value (l/min) flashes
Press the button.
The value (l/s) flashes.
Press the button.
The new value (l/s) is stored and the next screen is displayed.
10.4 Changing the numerical values in data menus
The procedure for changing numerical values is the same for all menus.
In this example, the preset value for the flow at maximum current is changed from 1,000 l to
1,258 l.
Open the password-protected menu.
See Section 10.2 Opening a password-protected menu, Page 23.
As an example, select the parameter for the flow at maximum current.
The tens of thousands digit (01000.0) flashes
Press the button twice.