EasyManua.ls Logo

Gigabyte GA-P67A-UD5 - Page 90

Gigabyte GA-P67A-UD5
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix - 90 -
Figure 2
Figure 3
C. Conguring a RAID array
Create a RAID Array:
Move the selection bar to HBA 0: Marvell 0 and press <Enter>.
Marvell BIOS Setup (c) 2009 Marvell Technology Group Ltd.
Topology Information
Help
Vendor ID : 1B4B
Device ID : 91A3
Revision ID : B1
BIOS Version : 0.0.0.0000
Firmware Version : 2.1.0.1502
PCIe Speed rate : 5.0Gbps
CongureSATAas : IDEMode
HBA 0 : Marvell 0
Virtual Disks
Free Physical Disks
PD 0: WDC WD800JD-22L
PD 8: WDC WD800JD-22L
Marvell RAID on chip controller.
ENTER: Operation F10: Exit/Save ESC: Return
Marvell BIOS Setup (c) 2009 Marvell Technology Group Ltd.
Topology Information
Help
Port ID : 0
PD ID : 0
Type ID : SATA PD
Status : Uncongured
Size : 114472MB
Feature Support : 1.5G 48Bit
Current Speed : 1.5G Mode
Model : WDC WD800JD-22LS
Serial : WD-WMAM9W736333
FW version : 3.18
HBA 0 : Marvell 0
Virtual Disks
Free Physical Disks
* PD 0: WDC WD800JD-22L
* PD 8: WDC WD800JD-22L
Use space bar to select the free disks to be used in the array.
ENTER: Operation SPACE: Select F10: Exit/Save ESC: Return
Under Free Physical Disks, use the <Space> key to select the hard drives to be included in the RAID array.
The selected hard drive will be marked with an asterisk (*). After selecting the hard drives, press <Enter> to
proceed (Figure 3).

Table of Contents

Related product manuals