Cables
Mains supply cable must be approved for fixed installation. The external diameter can be 4–12 mm (M20 gland) or
1018 mm (M25 gland) as main choice, but different glands sizes can be supplied. Cross sectional area of the wires
can be between 1.5 and 6.0 mm
2
. The cable must have an earth wire and shielded cable is recommended to be
used.
Operation of MAX LED in emergency mode
MAX 600 LED 2200 give 16% light level at E1 and 9% at E3. MAX 1200 LED 4500 give 13% light
level at E1 and 6% at E3. When mains voltage is switched on the charging indicator (green LED) will light, indicating
charging of the battery. If the connection to the battery is disrupted or the battery is defect, the indicator will not light.
Reset fault indication by switching off/on power supply. A new or discharged battery must be charged for at least 24
hours in order to be full charged.
Battery pack replacement
When the battery pack is defect or need to be replaced, use only original battery pack from Glamox
4.8V 4.0Ah Item no: PA140818001 for MAX 600/1200 LED 3500/6500
7.2V 4.0Ah Item no: PM161012000 for MAX 600/1200 LED 2200/4500
Battery type is marked inside MAX LED.
Do not replace the battery when an explosive atmosphere is present.
Control and inspection
General inspection and main function control to be carried out once a month. Fully emergency duration test by
switching off power supply should be performed at least once a year and the specified emergency light time shall be
observed.
Maintenance
The MAX LED is designed to operate many years with a minimum need for maintenance. However it may be
necessary to clean the diffuser if it gets dirty. Do never use any solvents for cleaning polycarbonate diffuser due to risk
of generating static charge. Use moist cloth only, no solvent. If battery and other components need to be replaced, it
is important to use only original Glamox components.
Cycling of battery
To have best lifetime of batteries, cycle the batteries at least 2 times by charging for 24 h and discharge until the
emergency light turns off. To cycle, just switch the circuit breaker on/off.