EasyManua.ls Logo

Global Specialties 5001 User Manual

Global Specialties 5001
41 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
500
1
u]$VERSAL
COUNTER-TIMER
INSTRUCTION,
OPERATION
AND
APPLICATION
MANUAL
80-o1-oo37
1t88
GLOBAL
SPECIALTIES
1486
Highland
Avenue,
Unit 2
Cheshire,
CT 06410
(203)272-3285Tel.
(203)2724330Fpx
Question and Answer IconNeed help?

Do you have a question about the Global Specialties 5001 and is the answer not in the manual?

Global Specialties 5001 Specifications

General IconGeneral
BrandGlobal Specialties
Model5001
CategoryTimer
LanguageEnglish

Summary

5001 Specifications

Input Specifications

Details the impedance, response, sensitivity, and voltage limits of the inputs.

Measurement Modes

Explains the available measurement modes like Frequency, Period, and Ratio.

Accuracy and Performance

Outlines the precision and performance standards of the device.

Instrument Features

Covers controls, display, power, dimensions, and operating temperature.

Introduction to the 5001 Counter-Timer

Front Panel Controls and Operation

Power and Mode Selection

Describes the power switch and primary measurement mode selection buttons.

Measurement and Timing Controls

Details RUN, HOLD, RESET, and delay/gate time selectors.

Signal Conditioning Controls

Explains input attenuation, trigger level, and slope selection for signal accuracy.

Rear Panel Interface

Describes the internal/external timebase switch and input connector.

Initial Inspection and Checkout Procedure

Checkout Procedure

Step-by-step guide to verify instrument functionality and initial setup.

Operating Instructions

Frequency Counter Operation

Instructions for performing frequency measurements using the instrument.

Period Measurement

Instructions for measuring signal period and calculating frequency.

Frequency Ratio Measurement

Guide to measuring the ratio between two input frequencies.

Time Interval Measurement

Instructions for measuring time between signal edges and pulse widths.

Event Counter Operation

How to use the instrument to count events or signal edges.

Signal Conditioning

Guidelines for adjusting attenuation, trigger level, and slope for optimal signal input.

Display Hold and Delay

Explains the function of holding the display and introducing delays between measurements.

External Timebase Usage

Details how to use an external timebase for enhanced accuracy and range.

Maintenance and Calibration

Fuse Replacement

Procedure for replacing the instrument's fuse.

Recalibration Procedure

Steps for recalibrating the instrument's accuracy.

Case Disassembly

Step-by-step instructions for opening the instrument's case.

Case Reassembly

Step-by-step instructions for closing the instrument's case.

Functional Description

Circuit Description

Applications

Frequency Counter Applications

Examples and guidance for using the instrument as a frequency counter.

Period Measurement Applications

Examples of using the instrument for period measurements.

Time Interval Applications

Examples of measuring time intervals and pulse parameters.

Frequency Ratio Applications

Guidance on using the instrument for frequency ratio measurements.

Event Counter Applications

Examples of using the instrument to count events.

External Timebase Applications

Examples of using the external timebase for extended measurements.

Service and Warranty Information

Factory Service and Repair

Information on obtaining service and repair for the instrument.

Product Warranty

Details the warranty terms and conditions for the device.