46
4000123942-2
18 Replacement of Parts
18.16 User interface board, refer to diagram
18.10.
Before starting refer to the front of Section 18 Important
information.
• Remove the front panel, refer to Section 15.3.
• Unclip control panel user interface and hinge forward . Do not
strain the cables.
• Disconnect the electrical connections from the user inter face
board.
• Remove the two user inter face board retaining screws.
• Remove the user inter face board.
18.17 Mains switch, refer to diagram 18.10.
Before starting refer to the front of Section 18 Important
information.
• Remove the front panel, refer to Section 15.3.
• Unclip control panel user interface and hinge forward . Do not
strain the cables.
• Disconnect the electrical connections from mains switch.
• Remove the mains switch.
18.18 230V Controls board, refer to diagram
18.10.
Before starting refer to the front of Section 18 Important
information.
• Remove the front panel, refer to Section 15.3.
• Unclip control panel user interface and hinge forward . Do not
strain the cables.
• Disconnect the electrical connection from the 230V controls
board and the electrical connection from printed circuit board
(PCB).
• Remove the 230V controls board retaining screw.
• Remove the 230V controls board.
18.19 (24ci Only) Analogue programmer, refer
to diagram 18.10
Before starting refer to the front of Section 18 Important
information.
• Remove the front panel, refer to Section 15.3.
• Unclip control panel user interface and hinge forward. Do not
strain the cables.
• Disconnect the electrical connection from the programmer.
• Undo the two securing screws and remove the programmer.
18.20 Central heating pump head, refer to
diagram 18.11.
Before starting refer to the front of Section 18 Important
information.
• Remove the front panel, refer to Section 15.3.
• Lower the control panel, refer to Section 15.4.
• Drain down central heating water circuit of the boiler only,
refer to relevant part of diagram 18.1.
Note: it is not necessary to drain down the entire heating
system to carry out this work.
• For ease of access if required remove the right hand side
panel, refer to Section 15.6.
• Undo four head fixing screws and remove pump head.
• Gain access to the pump electrical connection box and
remove cover.
• Disconnect pump cable from pump (avoid straining cables).
• Connect electrical connection to replacement pump head.
• Fit replacement pump head.
Diagram 18.11
9823
PUMP
HEAD
PUMP
ELECTRICAL
CONNECTION
BOX
HEX HEAD SCREW (4 OFF)
CONTROL PANEL
11659
Diagram 18.10
USER INTERFACE BOARD
11660
MAINS SWITCH230V CONTROLS BOARD
24ci shown
PROGRAMMER
24ci shown