EasyManua.ls Logo

Glow-worm Economy Plus 60F - Page 19

Glow-worm Economy Plus 60F
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Supplied By www.heating spares.co Tel. 0161 620 6677
19
221504A
Diagram 7.3INTERNAL FLUE ASSEMBLY
Diagram 7.4
FLUE ASSEMBLY /
BOILER CONNECTION
Diagram 7.5
FLUE ELBOW SPIGOT
GASKET
WASHER (3)
SECURING
SCREW (3)
FLUE ELBOW
SPIGOT
FAN RETAINING
BRACKET
693435543344
Diagram 7.2
FLUE PREPARATION
7 Flue Assembly Installation
FAN ELECTRICAL
CONNECTIONS
AIR PRESSURE
SWITCH TUBES
RED
CLEAR
SECURING
SCREW (4)
FAN / MOUNTING
PLATE ASSY.
SECURING
SCREW (2)
COMBUSTION
CHAMBER
FRONT PANEL
FLUE HOOD
WING NUTS
3303
7.3 Internal Flue Installation
Push the flue assembly into and through the wall, see diagram
7.3.
7.4 Flue/Boiler Connection
Secure the flue elbow and gasket to the boiler with the three
screws and washers, previously removed, see diagram 7.4.
Replace the fan and mounting plate assembly ensuring
engagement of the fan into the flue elbow and the fan retaining
bracket, see diagram 7.5 and secure with the two screws
previously removed.
Connect the air pressure switch tubes and electrical connections.
Make good around the flue and flue terminal and fit the terminal
guard.