7 S e r v i c i n g
7.1 Notes.
(a) To ensure the continued efficient and safe operation
of the appliance it is recommended that it is checked
and serviced at regular intervals. The frequency of
servicing will depend upon the particular installation
and usage, but in general once a year should be
enough.
(b) It is the law that any servicing must be carried out by
a competent person.
(c) Make sure the fire front is cold before carrying out
any servicing.
(d) BEFORE SERVICING ISOLATE THE GAS AND
ELECTRICAL SUPPLIES.
(e) After servicing of parts always test for gas
soundness with a suitable leak detection fluid.
To test the gas tap apply leak detection fluid to all
joints, light the burner and check all the joints for
leakage at all tap settings.
WARNING: Take care as the burner flame is fully
exposed.
(f) Carry out functional check on controls.
(g) After removing or disconnecting any pipe work
always make sure that it is refitted correctly and
does not interfere with the fitting of the fire front.
(h) Unless stated otherwise reassembly of all
components should be in the reverse order to that for
removal.
(j) It is recommended that the back boiler be serviced at
this time.
Refer to Back Boiler Installation and Servicing
Instructions.
7.2 Fire Front - Castings
Remove the ash pit cover by unhooking from the fret,
take care as there are wires attached, see diagram 5.12.
The ash pit cover can be left attached by the harness to
the micro switch/gas tap.
Remove the fret by unhooking from the fire surround,
see diagram 5.10.
When removing the fire front, first remove the M4 screw
from the base of the combustion chamber assembly, see
diagram 5.3. Lift the fire front up to clear the location
pins, see diagram 5.3.
Take care when removing the fire front as it is heavy.
GAS INLET
UNION
GAS INLET
UNION
L.H. BURNER
MOUNTING
SCREW
ELECTRODE
BRACKET
SECURING
NUT
THERMOCOUPLE
LOCK NUT
INJECTOR
L.H. MOUNTING
BRACKET
WING NUT
THERMOCOUPLE BRACKET
4028