Loading...
Supplied By www.heating spares.co Tel. 0161 620 6677
37
220692C
37
SECTION
10
Servicing
step
6
step
8
step
7
3050
FAN/FLUE HOOD
SCREW (2)
SPLIT PIN
OVERHEAT
CUT-OFF
PHIAL
Cleaning the Heat
Exchanger
Slacken the flue hood by loosening the
extended brass screws at the left and
right hand sides.
Remove the split pin and thermostat
phials from the pocket, taking care
not to kink the capillaries.
When replacing the phials make sure
that they are still covered with heat
sink compound.
Disconnect the air pressure switch
tubes.
WHITE
AIR
PRESSURE
SWITCH
TUBES
RED
THERMOSTAT
PHIAL
PHIAL
POCKET