Loading...
Supplied By www.heating spares.co Tel. 0161 620 6677
40
220692C
40
SECTION
Servicing
10
step
15
4781
SPARK GAP
3.5-4.5mm
15-20mm
Pilot Burner, Ignition
Electrode and Pilot
Injector
Pull off the ignition lead at the
electrode (covered with a silicone
rubber sleeve).
Unscrew the tubing nuts at both ends
releasing the pilot pipe.
Remove the pilot burner securing
screws to release the pilot burner and
electrode assembly.
Clean the pilot burner and electrode.
Remove the pilot injector by
unscrewing it from the pilot burner,
clean it by blowing through it.
When refitting take care not to damage
the electrode and check that the spark
gap is as shown.
PILOT TUBING NUT
SILICONE
RUBBER
SLEEVE
PILOT
BURNER
ASSEMBLY
SECURING
SCREW (2)
IGNITION
LEAD
PILOT
PIPE
PILOT TUBING NUT
PILOT BURNER
PILOT INJECTOR