Supplied By www.heating spares.co Tel. 0161 620 6677
5
220692C
5
SECTION
General
1
Range Rating
The boiler is range rated and may be
adjusted to suit individual system
requirements, refer to the relevant
column of the table.
Data Table
in wg 5.6 5.9
mbar 14.0 14.6
Btu/h 50000 60000
kW 14.66 17.59
in wg 4.9 5.2
mbar 12.2 13.0
in wg 4.2 4.6
mbar 10.6 11.4
Btu/h 60000 70000
kW 17.59 20.52
Btu/h 55000 65000
kW 16.12 19.05
Nominal min
Heat med
Input max
(Gross)
Nominal min
Heat med
Ouput max
Burner min
Setting med
Pressure max
Space Saver Space Saver
Range Rating K.F.B K.F.B
60 70
Btu/h 70064 84416
kW 20.54 24.74
Btu/h 75000 89709
kW 21.98 26.29
Btu/h 64935 78947
kW 19.03 23.14
Data Label Position
3038
Space Saver Space Saver
Model K.F.B K.F.B
60 70
Lifting 32.4kg 32.4kg
Weight (71.4lb) (71.4lb)
Total 46.1kg 46.1kg
Weight (dry)* (101.6lb) (101.6lb)
Water 2.13 litres 2.13 litres
Content (0.47 gal) (0.47 gal)
Gas Rc
1
/
2
Rc
1
/
2
Connection (
1
/
2
" BSPT) (
1
/
2
" BSPT)
Water 28mm 28mm
Connection Compression Compression
Electrical 240V~50Hz fused 3A max
supply
Internal Fuse to BS4265 sheet 2. Type F1A
Fuse Rating
Power rating 55W
* Note: The weight of the water is negligible
Space Saver K.F.B 70
G.C. Number 41 319 12
Space Saver K.F.B 60
G.C. Number 41 319 11