9.2 Horizontal Telescopic Flue - A2043600
Refer to diagram 9.2 for kit contents.
9.3 REAR Flue
If a wall thickness is between 203mm min. to 413mm max.
then the flue can be used without extensions.
With the flue elbow temporarily fitted, measure the distance
from the outside wall to the butt joint, see diagram
9.4. If
the measurement ‘Y’ exceeds 525mm, then the appropriate
length of extension pipe is required.
If the dimension is less than 315mm DO NOT cut the flue, it
can project to a maximum of 600mm, see diagram 9.5. If this
is not desirable then a Standard flue MUST be used and cut
to length.
9.4 SIDE Flue
With the flue elbow temporarily fitted, measure the distance
from the outside wall to the butt joint, see diagram 9.6. If
the measurement ‘Y’ exceeds 525mm, then the appropriate
length of extension pipe is required.
If the dimension is less than 315mm DO NOT cut the flue, it
can project to a maximum of 600mm, refer to diagram 9.5, if
this is not desirable then a Standard flue MUST be used and
cut to length.
Diagram 9.4
13223
Diagram 9.5
12979
9 Telescopic Flue - Length, Preparation and Installation
Diagram 9.6
13224
REAR FLUE
SIDE FLUE
FLUE TERMINAL
Left Hand illustrated