9.7 Standard Horizontal Flue
Refer to diagram 9.11 for kit contents.
9.8 REAR Flue
With the flue elbow temporarily fitted, measure the distance
from the outside wall to the butt joint, see diagram
9.13. If
the measurement ‘Y’ exceeds 665mm, then the appropriate
length of extension pipe is required. The minimum
dimension is 187mm to suit a 75mm min wall thickness. The
flue can project to a maximum of 600mm, if this is desirable,
refer to diagram 9.14.
9.9 SIDE Flue
With the flue elbow temporarily fitted, measure the distance
from the outside wall to the butt joint, see diagram 9.15. If
the measurement ‘Y’ exceeds 665mm, then the appropriate
length of extension pipe is required. The minimum dimension
for Lhd is 255 and Rhd 149 to suit a minimum wall thickness
of 75mm. The flue can project to a maximum of 600mm, if
this is desirable, refer to diagram 9.14.
13224
Diagram 9.15
Left Hand illustrated
9 Standard Flue - Length, Preparation and Installation
Diagram 9.13
13223
Diagram 9.14
12979
REAR FLUE
SIDE FLUE
FLUE TERMINAL