36
10 Electrical Connection
10.4 Electrical Cartridge Securing
Close the cartridge and secure with the previously removed
screw.
Push the electrical cartridge into the interface housing on
completion of the wiring, see diagram 10.3.
Secure with the two cartridge retaining screws provided in the
cartridge body.
10.5 Electrical Connections - Testing
Carry out preliminary electrical system checks as below:
1. Test insulation resistance to earth of mains cables.
2. Test the earth continuity and short circuit of cables.
3. Test the polarity of the mains.
NOTE: If you require to test the appliance refer to section 13.
13301
Diagram 10.3
ELECTRICAL
CARTRIDGE
FIXING
SCREWS
Diagram 10.2
230Vac SYSTEM
CONTROLS
- Zone valve
- Programmer
- Room thermostat
- Cylinder thermostat
NOTE: ALL CABLES
CONNECTED TO THE
APPLIANCE SHOULD
BE PERMANENTLY
FIXED TO THE WALL
L
N
E
PUMP
NOTE: This appliance
will not operate without
a link or system
controls fitted.
13457