0020112600_02-10/12-Glow-worm
- 28 -
INSTALLATION
   




d.34 Speedoffan rpm
Fanspeedisdisplayedbetween0and99.
Multiplythedisplayedvalueby100.
- no
d.40 Heatingowtemperature °C Displaytheheatingowtemperature. - no
d.41 Heatingreturntemperature °C Displaytheheatingreturntemperature. - no
The following 2 menus are displayed if an outdoor sensor (not supplied) is installed on the appliance.
d.43 Heatingcurve K
Seetheinstructionsfortheexternalsensorconnectedtothe
appliance.
1.2 yes
d.47 Exteriortemperature °C Displaythetemperaturemeasuredbytheexternalsensor. - no
d.67
Timeremainingbeforetheendofthe
anti-cycleinheatingmode.
min. Displaythetimeremainingbeforetheendoftheanticycle. - no
d.71
Maximumtemperaturesettingfor
heatingoutlet
°C Selectavaluebetween50°Cand80°C. 75 yes
d.90 DetectionofeBUScontroller -
0=Notdetected
1=Detected
- no
 
• Pressformorethan7secondsonthebutton to
accessthecongurationmenu.Thescreendisplays"0".
• Pressonbutton
or underthesymbol andenterthe
AfterSalesServicepassword.
• Presson
tovalidate.Thescreendisplaysthe
parameter"00"anditsvalue"XX”.
• Pressonbutton
or underthesymbol toaccessthe
parametertomodify.
• Pressonbutton
or underthesymbol tomodifythe
valueoftheparameter.
• Repeattheprocessforeachparametermodied.
• Pressformorethan3secondsonthebutton
toexit
thecongurationmenu.
   




d.08 Currentstateofthe230Vroomthermostat -
230Vroomthermostat:
0=open(noheating),
1=closed(heatingmode).
- no
d.09 FlowtemperaturesetpointfromexternaleBuscontrol °C ExternaleBussetvalue. - no
d.10 Pumpstatus -
0=off
1=on
- no
d.16 Currentstateofthe24Vroomthermostat °C
0=open(noheating),
1=closed(heatingmode)
- no
d.17 FloworReturntemperaturecontrol °C
Temperatureregulationonow(radiator)orreturn
(under-oorheating)temperaturesensor.
0 yes
d.21 DHWstatus -
0=DHWfunctiondisabled
1=DHWactivated
- no
d.22 DHWmode(eBusanddirectconnectiontoboard) -
0=off
1=on
- no
d.23 Centralheatingmode -
0=CHnotavailable(summermode)
1=CHavailable(wintermode)
- no
d.25 DHWmode -
DHWloadingenabledordisabledbyAppliance
InterfaceorEbusorexternalcontrols.
- no
d.33 Speedsetpointoffan rpm
Fanspeedisdisplayedbetween0and99.
Multiplythedisplayedvalueby100.
- no
d.44 Digitalizedionisationvoltage V Displaythedigitalizedionisationvoltage - no