ELECTROLYTIC CHLORINE GENERATOR
BASIC POOL MAINTENANCE REQUIREMENTS
WEEKLY
MONTHLY
QUARTERLY
Electronic Chlorine Generator
www.goldlinecontrols.com
N. Kingstown, RI 02852 USA
092392C
Copyright © 2009 Goldine Controls
LD
C
G
LINE
ON
T
ROLS
LD
C
G
LINE
ON
T
ROLS
Shown with optional AQL-CHEM Chemistry Kit
Operation and Installation
Manual
AQR-PRO
Free Chlorine 1.0 - 3.0 ppm
pH 7.2 - 7.8
Raise desired output % to
increase, lower desired output %
to decrease -OR- increase or
decrease pump filtration time.
Too low - add soda ash.
Too high - add muriatic acid
Alkalinity 80 - 120 ppm
Salt 2700 - 3400 ppm Add salt as required to increase.
Add baking soda to increase.
Stabilizer 60 - 80 ppm Add cyanuric acid to increase.
Calcium 200 - 400 ppm Add calcium to increase.
Electrolytic Cell inspect & clean Refer to section in manual.
TEST IDEAL RANGE ADJUSTMENT REQUIRED
Drain and add water to decrease.
A
dd acid as required to decrease.

Other manuals for Goldine Controls Aqua Rite

Question and Answer IconNeed help?

Do you have a question about the Goldine Controls Aqua Rite and is the answer not in the manual?

Goldine Controls Aqua Rite Specifications

General IconGeneral
BrandGoldine Controls
ModelAqua Rite
CategoryLighting Equipment
LanguageEnglish

Summary

IMPORTANT SAFETY INSTRUCTIONS

General Safety Precautions

Covers warnings regarding children, conductor types, power disconnect, and general usage advice.

Grounding and Bonding Requirements

Details requirements for bonding lugs, ground terminals, and connecting metal components to the bonding grid.

OPERATION

Water Chemistry Parameters

Details recommended levels for salt, chlorine, pH, alkalinity, and stabilizer.

Salt Level Management

Covers ideal salt levels, recommended salt types, and procedures for adding/removing salt.

INSTALLATION

Plumbing Connections

Details plumbing requirements for the flow switch and electrolytic cell, including pipe size and configuration options.

Wiring and Power Input

Covers wiring the unit, power supply requirements, and grounding connections.

TROUBLESHOOTING

Check System Indicator Guide

Explains common 'Check System' alerts like 'Inspect Cell' and 'Low Salt/Minerals'.

Error Condition Diagnosis

Details various error codes including cell sensor issues, voltage problems, and probe errors.