Example command file using gseq. ‘002commandfile.txt’
/lims=1; first message number of group will be named
021name.mp3
/lime=3; Last message number of group will be named
023name.mp3
/gseq=2; Trip 2 is calling this group sequencer
/wtan=0100; Wait for end of MP3 before exiting
);
cmnd Switch to new command file
Cancels and saves any playing mp3 and also saves current position of
command file. Searches for new command file and if found will run the
new command file. It is possible to manually hold the mp3 and release it
in the new command file using the ‘hold’ command. Or hold it in the first
command file and release the mp3 after returning back to the original
command file.
If the new cmd file is non-existent, the next command line in the calling
file will run.
This command also allows longer command files than 64 lines by daisy
chaining them and also allows interaction etc.
If /cont=1 is set in the ‘ctl’ file the first cmd file will continue from where it
Left from after the interrupting file has ended.
/cmnd=4; Jumps to command file 004xxxx.txt
autp Modify or clear the auto run mode.
This command modifies the ’/autp=?;’ command in the ‘ctlxxx.txt’ file
which allows you to disable the automatically playing file.
/autp=1;
vlup Increment volume by amount specified.
This command will raise the volume by the amount specified following the
command. This can be used to increase the volume while a trip line is
held active by using the ‘cond’ command and ‘trip’ commands to create a
conditional loop.
You must set ‘vlmx’ in ctl.txt file to set the max limit for this command.
The ‘pvol’ parameter must be set to the initial level for power up and it
must not be set to 0.
/vlup=1;
vldn Decrement volume by amount specified.
This command will decrease the volume by the amount specified follow-
ing the command. This can be used to decrease the volume while a trip
line is held active by using the ‘cond’ command and ‘trip’ commands to
create a conditional loop.
You must set ‘vlmn’ in ctl.txt file to set the min limit for this command.
The ‘pvol’ parameter must be set to the initial level for power up and it
must not be set to 0.
/vldn=1;
Command files
DMS3000 V2.20
Digital Audio Playback Card
Golding Audio Ltd
Unit 8
Peartree Business Centre
Stanway Colchester
Essex CO3 0JN
Tel: 01206 762462 Fax: 01206 762633
Web Site: www.goldingaudio.co.uk
Golding Audio Ltd reserve the right to change specification of this or any product without prior notice being given. Golding Audio will not be held
responsible for any damage caused to any equipment or data, arising from use of the product mentioned herein.