18
MODULE PROGRAMMING
Programming fields:
Continued overleaf
Continued from previous page
Field “6”: Configuring locking mode.
6
Press 6 to select field 6.
Steps: Field + locking mode + time between attempts + lock time + panic output + key button.
7 C
or
(Step 1)
(Step )7
Set the access control module's locking mode.
Enter one of the following options:
0: Never locks.
3 to 9: Locks after 3 to 9 failed attempts to enter the user pin.
Allows the access control module's locking mode to be configured.
1
0
(Step )3
Set the minimum amount of time that must elapse between failed attempts before the
access control module is locked. Only takes effect if option 0 has not been selected in
step 2.
The times to select are 01 to 15 minutes or press the key button.
Note: If the key button is pressed, this field value is set as 03 , the locking timeminutes
field value is 03 , the panic output value field is 0 and theminutes not activated
programming of the field finishes
.
(Step )6
Press the key button to finish programming the field.
Note: It is not necessary to press the key button if it has already been pressed in steps
3, 4 or 5.
Then press the number of the next field to configure or press the C button (cancel) to exit
programming mode.
6
0
0
(Step )2
0 1
or
(Step )4
Set the amount of time that the access control module remains in locking mode after the
last wrong code has been entered. Only takes effect if option 0 has not been selected in
step 2.
The times to select are 03 to 15 minutes or press the key button.
Note: If the key button is pressed, the field value is set as 03 , the panic outputminutes
value field is 0 and the programming of the field finishesnot activated
.
1
0
*
( )
*
( )
0 30 1
*
( )
*
( )
(Step )5
Set the activation of the panic output (terminal P of the terminal block) during locking
mode. Only takes effect if option 0 has not been selected in step 2.
Enter one of the following options or press the key button:
0 : Output not activated.
1 : Output activated (for 3 seconds in intervals of 1 minute).
Note: If the key button is pressed, the field value is set as 0 and the programming of the
field finishes.
1
0
*
( )
*
( )
or
AUDIO AND VIDEO DOOR ENTRY SYSTEM - ACCESS CONTROL