BLOWER PERFORMANCE DATA
17
ARPF
Note: Assumes dry coil with filter in place; SCFM correction for wet coil = 4% (208V/240V)
0.1" 0.2" 0.3" 0.4" 0.5"
High 1155 1090 1025 950 895
ARPF18241* Med. 940 890 860 815 755
Low 695 665 650 610 550
High 1135 1085 1025 965 915
ARPF19311* Med. 860 825 780 750 680
Low 600 570 545 500 465
High 1385 1315 1240 1155 1065
ARPF30301* Med. 1340 1290 1230 1140 1050
Low 1075 1030 980 910 840
High 1310 1240 1155 1090 1020
ARPF36361* Med. 1270 1210 1140 1075 980
Low 1045 1005 955 885 805
High 1700 1660 1625 1545 1505
ARPF36421* Med. 1500 1440 1400 1350 1345
Low 1330 1300 1250 1230 1220
High 2065 2000 1925 1860 1780
ARPF37431* Med. 1685 1635 1550 1470 1410
Low 1490 1425 1345 1280 1205
High 2150 2120 2070 2000 1940
ARPF48601* Med. 1940 1930 1905 1860 1790
Low 1610 1600 1590 1575 1550
High 2150 2105 2040 1970 1880
ARPF49611* Med. 1960 1935 1895 1825 1750
Low 1670 1625 1585 1525 1455
CFM deliverd against External Static Pressure
Model Speed