14 www.goodmanmfg.com
www.goodmanmfg.com 15
Airflow Data — GMEC961205DN
COOLING
Dipswitch Setting:
Switch Bank 2
Switch 1 2 3
Static
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
CFM CFM CFM CFM CFM CFM CFM CFM
G 1796 1753 1697 1645 1589 1536 1478 1425
Ylo 1017 855 N/A
Y 1511 1445 1387 1340
Ylo 1017 855 N/A
Y 1327 1185 1118 1051
Ylo 1327 1185 1118 1051
Y 1511 1445 1387 1340
Ylo 1327 1185 1118 1051
Y 1753 1478 1425
Ylo 1327 1185 1118 1051
Y 2211 2122
Ylo 1017 855 N/A
Y 1511 1445 1387 1340
** Factory Default
HEATING
Dipswitch Setting:
Switch Bank 3
Switch 1 2
Static
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM
41 1753 42 44 45 47 1478 1425
2211 48 2122 50 51 52
1017 73 N/A 855 N/A N/A N/A
2211 48 2122 50 51 52
1017 73 N/A 855 N/A N/A N/A
75 1327 N/A N/A 1185 N/A 1118 N/A 1051
53 1327 1185 1118 1051
1511 70 1445 73 1387 1340
** Factory Default