4 www.goodmanmfg.com SS-GMH95
SS-GMH95 www.goodmanmfg.com 5
Product SPecificationS
Product SPecificationS
GMH95 diMensions
Model A B C D E
GMH950453BXA
17½” 16”
GMH950703BXA
17½” 16”
GMH950704CXA
21” 19½” 16” 17½”
GMH950904CXA
21” 19½” 16” 17½”
GMH950905CXA
21” 19½”
GMH951155DXA
24½” 23”
Notes:
Right: Straight pipe to reach gas valve
MiniMuM ClearanCes to CoMbustible Materials
Position Sides Rear Front Bottom Flue Top
0” 0” 1” C 0” 1”
Horizontal 6” 0” 1” C 0” 4”
For servicing or cleaning, a 24” front clearance is recommended.
• In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.
COMPONENT IDENTIFICATION
6
GMH95*****XA*
Cabinet Size A B C D E
13-5/8
17-1/2
20-7/8
All dimensions are in inches.
24-1/2
12-1/8
16
19-3/8
12-15/16
15-15/16
20-7/16
GMH950453BXA*
GMH950703BXA*
GMH950704CXA*
GMH950904CXA*
GMH950905DXA*
GMH951155DXA*
16
19-1/2
23
17-1/2
21
RIGHT SIDE
DRAIN LINE
HOLES
AIR
INTAKE
PIPE
2" PVC
1 5/8
RIGHT SIDE VIEW
2
1 1/2
UNFOLDED FLANGES
1
FOLDED FLANGES
UNFOLDED FLANGES
FOLDED FLANGES
AIR
DISCHARGE
AIR
DISCHARGE
NOTE: Airflow area will be reduced by approximately 18% if duct flanges are not unfolded. This could cause performance issues and
noise issues.
19 7/8”