EasyManua.ls Logo

Goodman GMS8 - Pressure Switch Trip Points; Primary Limit; Rollout Limit Switches; Auxiliary Limit Switches

Goodman GMS8
14 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
PRODUCT DESIGN
For installations in Canada, the GMS furnaces are certifed only to 4,500 ft.
* Negative pressure readings are in inches of water column (*w.c.)
GMS8
Model
Trip Point
ID Blower
Pressure
Switch
ID Blower
Pressure
Switch
Part #
GMS80453A*C*
-0.70 B1370158
GMS80703A*C*
-0.70 B1370158
GMS80704B*C*
-0.75 B1370179
GMS80904B*C*
-0.75 B1370179
GMS80905B*C*
-0.75 B1370179
GMS81155C*C*
-0.90 0130F00041
GMS81405D*C*
-0.80 0130F00042
Pressure Switch Trip Points
Part Number 0130F00035 20162906 20162903 0130F00036
Open Setting (°F)
220 170 160 180
GMS80453A*C*
1 --- --- ---
GMS80703A*C*
--- 1 --- ---
GMS80704B*C*
--- 1 1 ---
GMS80904B*C*
--- --- 1 ---
GMS80905B*C*
--- --- --- 1
GMS81155C*C*
--- --- --- 1
GMS81405D*C*
--- --- 1 ---
PRIM ARY LIMIT
Part Number 10123529
Open Setting (°F)
300
GMS80453A*C*
2
GMS80703A*C*
2
GMS80704B*C*
2
GMS80904B*C*
2
GMS80905B*C*
2
GMS81155C*C*
2
GMS81405D*C*
2
ROLLOUT LIMIT SWITCHES
Part Number 0130F00038
Open Setting (°F)
120
GMS80453A*C*
1
GMS80703A*C*
1
GMS80704B*C*
1
GMS80904B*C*
1
GMS80905B*C*
1
GMS81155C*C*
1
GMS81405D*C*
1
AUXILIARY LIMIT SWITCHES

Other manuals for Goodman GMS8