SYSTEM OPERATION
86
TROUBLESHOOTING CHART
1
Integrated control module will automatically attempt to reset from lockout after one hour.
2
LED Flash code will cease if power to the control module is interrupted through the disconnect or door switch.
Turn power OFF
prior to repair.
Igniter is fragile,
handle with care.
Clean flame
sensor with steel
wool.
See “Combustion
and Ventilation Air
Requirements”
and “Category I
Venting (Vertical
Venting)” section
for details.
See Product Data
Bulletin for
allowable rise
range and proper
circulator speed.
Turn power OFF
prior to repair.
Replace pressure
switch with
proper replace-
ment part.
Read precautions
in “Electrostatic
Discharge”
section of manual.
Turn power OFF
prior to repair.
Replace integrated
control module
fuse with 3A
automotive fuse.
Cautions and Notes
Furnace lockout due
to an excessive
number of ignition
attempt (1 total) and
“retries” (2 total)
1
.
After a total of 3
tries for ignition,
lockout occurs.
"Recycles" are
infinite.
Auxiliary Limit Open
Locate and correct
gas interruption.
Replace or realign
igniter.
Check flame sense
signal. Sand sensor if
coated and/or
oxidized.
Check flue piping for
blockage, proper
length, elbows, and
termination.
Verify proper induced
draft blower perfor-
mance.
Check circulator
blower speed and
performance. Correct
speed or replace
blower if necessary.
Furnace fails to operate.
Integrated control
module diagnostic LED
is flashing ONE (1)
flash.
1
1 FLASH
Failure to establish flame.
Cause may be no gas to
burners, bad igniter or
igniter alignment, improper
orifices, or coated/
oxidized or improperly
connected flame sensor.
Loss of flame after
establishment. Cause may
be interrupted gas supply,
lazy burner flames
(improper gas pressure
or restriction in flue or
improper induced draft
blower performance.
Insufficient conditioned air
over the heat exchanger.
Blocked filters, restrictive
ductwork, improper
circulator blower speed,
or failed circulator
blower.
Pressure switch
circuit is closed.
Induced draft
blower is not
operating.
Replace induced draft
blower pressure
switch.
Repair short.
Furnace fails to
operate.
Integrated control
module diagnostic LED
is flashing TWO (2)
flashes.
2
Induced draft blower
pressure switch contacts
sticking.
Shorts in pressure switch
circuit.
Inspect pressure
switch hose. Repair,
if necessary,
Inspect flue for
blockage, proper
length, elbows, and
termination.
Correct pressure
switch setpoint or
contact motion.
Tighten or correct
wiring connection.
Pressure switch hose
blocked, pinched or
connected improperly.
Blocked flue or weak
induced draft blower.
Incorrect pressure switch
setpoint or malfunctioning
switch contacts.
Loose or improperly
connected wiring.
Pressure switch
circuit not closed.
Induced draft
blower is operating.
Induced draft blower
runs continuously with
no further furnace
operation.
Integrated control
module diagnostic LED
is flashing THREE (3)
flashes.
3
3 FLASHES
Turn power OFF
prior to repair.
See “Combustion
and Ventilation Air
Requirements”
and “Category I
Venting (Vertical
Venting)” section
for details.
Replace pressure
switch. with
proper replace-
ment part.
Integrated control
module has an
internal fault.
Integrated control module
has an internal fault.
Replace bad integrated
control module.
Furnace fails to
operate.
No 115 volt power
to furnace, or no 24
volt power to
integrated control
module.
Blown fuse or
circuit breaker.
Manual disconnect switch
OFF, door switch open, or
24 volt wires improperly
connected or loose.
Blown fuse or circuit
breaker.
Assure 115 and 24 volt
power to furnace
integrated control
module.
Check integrated control
module fuse (3A).
Replace if necessary.
Check for possible
shorts in 115 and 24 volt
circuits. Repair as
necessary.
Furnace fails to
operate.
Integrated control
module diagnostic LED
provides no signal.
NONE
Fault Description(s) Possible Causes Corrective Action
Symptoms of Abnormal
Operation
Associated
LED Code
2
2 FLASHES
AMH8, AMS8, ADS8, DDS8, DMS8, DHS8,
GME8, GMH8, GMS8, GDS8, GHS8