9
PRODUCT DESIGN
LOW
FIRE
HIGH
FIRE
LOW
FIRE
HIGH
FIRE
LOW
FIRE
HIGH
FIRE
LOW
FIRE
HIGH
FIRE
GMV950453BX*
GMV950704CX*
-0.45 -0.90 -0.50 -0.95 -0.25 -0.25 -0.25 -0.25
GMV950905DX*
GMV951155DX*
-0.65 -1.20 -0.70 -1.25 -0.25 -0.25 -0.25 -0.25
GCV90704CX*
-0.35 -0.70 -0.20 -0.55 -0.52 -0.52 -0.37 -0.37
GCV90904DX*
-0.35 -0.70 -0.20 -0.55 -0.52 -0.52 -0.37 -0.37
GCV91155DX*
-0.35 -0.70 -0.20 -0.55 -0.52 -0.52 -0.37 -0.37
(2) Data given is least negative pressure required for pressure switch to remain closed.
Note: The typical sea level negative pressure data represents the minimum pressures expected. Shorter
length of flue pipe or single pipe systems compared to dual pipe systems should show higher (greater
negative) pressures.
PRESSURE SWITCH TRIP POINTS AND USAGE CHART
NEGATIVE
PRESSURE
ID BLOWER
WITH FLUE
NOT FIRING
TYPICAL SEA
LEVEL DATA
(1)
NEGATIVE
PRESSURE
ID BLOWER
WITH FLUE
FIRING
TYPICAL SEA
LEVEL DATA
(2)
NEGATIVE
PRESSURE
COIL COVER
WITH FLUE
NOT FIRING
TYPICAL SEA
LEVEL DATA
(1)
NEGATIVE
PRESSURE
COIL COVER
WITH FLUE
FIRING
TYPICAL SEA
LEVEL DATA
(2)
MODEL
(1) Data given is least negative pressure required for pressure switch to close.
LOW FIRE HIGH FIRE LOW FIRE HIGH FIRE LOW FIRE HIGH FIRE LOW FIRE HIGH FIRE
GMV950453BX*
GMV950704CX*
-0.10 -0.10 20197308 -0.30 -0.75 11177113 -0.10 -0.10 -0.22 -0.55
HAPS28
11177115
GMV950905DX*
GMV951155DX*
-0.10 -0.10 20197308 -0.50 -1.10 11177114 -0.10 -0.10 -0.38 -0.82
HAPS29
11177116
GCV90704CX*
-0.37 -0.37 20197313 -0.20 -0.55 11177118 -0.37 -0.37 -0.15 -0.30 HAPS31
GCV90905DX*
-0.37 -0.37 20197313 -0.20 -0.55 11177118 -0.37 -0.37 -0.15 -0.30 HAPS31
GCV91155DX*
-0.37 -0.37 20197313 -0.20 -0.55 11177118 -0.37 -0.37 -0.15 -0.30 HAPS31
7,001 ft. to 11,000 ft.
PRESSURE SWITCH TRIP POINTS AND USAGE CHART
Note:
All installations above 7,000 ft. require a pressure switch change. For installations in Canada the GMV95 & GCV9 furnaces are certified only to 4500 ft.
TRIP POINT
COIL COVER
PRESSURE SWITCH
TRIP POINT
COIL COVER
PRESSURE SWITCH
TRIP POINT
ID BLOWER
PRESSURE SWITCH
COIL COVER
PRESSURE
SWITCH
PART #
Note:
Replacement pressure switch number is listed below high altitude kit number.
Note:
All negative pressure readings are in inches of water column (" w.c.).
0 to 7,000 ft.
MODEL
TRIP POINT
ID BLOWER
PRESSURE SWITCH
HIGH
ALTITUDE
KIT
ID BLOWER
PRESSURE
SWITCH
PART #

Related product manuals