EasyManua.ls Logo

Goodman GMVC950453BXAA - Blower Performance Specifications; GMVC95;AMVC95 Heating Speed Charts

Goodman GMVC950453BXAA
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BLOWER PERFORMANCE SPECIFICATIONS
18
1. Units are shipped without filter(s). CFM in chart is without filter(s).
2. All furnaces shipped with heating speed set at "B" and cooling speed set at "D". Installer should adjust blower speed
as needed. The first task is to determine the proper aiflow for the cooling system.
3. For most cooling applications, about 400 CFM per ton is desirable.
4. The chart is for information only. For satisfactory operation, external static pressure not to exceed value shown on
rating plate.
5. Do not operate above 0.5" w.c. ESP in heating mode. Operating between 0.5" w.c. and 0.8" w.c. is tabulated for cooling
purposes only.
6. * Motor CFM minimum.
GMVC95/AMVC95 Heating Speed Charts
Heating
Speed
Tap
Adjus t
Tap
Low Stage
CFM
at .1" - .5" w.c.
ESP
High Stage
CFM
at .1" - .5" w.c.
ESP
Rise
(°F)
Heating
Speed
Tap
Adjus t
Tap
Low Stage
CFM
at .1" - .5" w.c.
ESP
High Stage
CFM
at .1" - .5" w.c.
ESP
Rise
(°F)
Minus(-) 495 713 57 Minus(-) 756 1,089 56
Normal 550 792 41 Normal 840 1,210 50
Plus (+) 605 871 46 Plus (+) 924 1,331 46
Minus(-) 540 778 52 Minus(-) 828 1,192 51
Normal 600 864 47 Normal 920 1,325 46
Plus (+) 660 950 43 Plus (+) 1,012 1,457 42
Minus(-) 585 842 48 Minus(-) 900 1,296 47
Normal 650 936 43 Normal 1,000 1,440 42
Plus (+) 715 1,030 39 Plus (+) 1,100 1,584 38
Minus(-) 630 907 45 Minus(-) 972 1,400 43
Normal 700 1,008 40 Normal 1,080 1,555 39
Plus (+) 770 1,109 36 Plus (+) 1,188 1,711 35
Heating
Speed
Tap
Adjus t
Tap
Low Stage
CFM
at .1" - .5" w.c.
ESP
High Stage
CFM
at .1" - .5" w.c.
ESP
Rise
(°F)
Heating
Speed
Tap
Adjus t
Tap
Low Stage
CFM
at .1" - .5" w.c.
ESP
High Stage
CFM
at .1" - .5" w.c.
ESP
Rise
(°F)
Minus(-) 1,013 1,458 56 Minus(-) 1,107 1,594 63
Normal 1,125 1,620 50 Normal 1,230 1,771 57
Plus (+) 1,238 1,782 45 Plus (+) 1,353 1,948 52
Minus(-) 1,076 1,549 52 Minus(-) 1,139 1,639 62
Normal 1,195 1,721 47 Normal 1,265 1,822 56
Plus (+) 1,315 1,893 43 Plus (+) 1,392 2,004 50
Minus(-) 1,139 1,639 49 Minus(-) 1,170 1,685 60
Normal 1,265 1,822 44 Normal 1,300 1,872 54
Plus (+) 1,392 2,004 40 Plus (+) 1,430 2,059 49
Minus(-) 1,202 1,730 47 Minus(-) 1,202 1,730 58
Normal 1,335 1,922 42 Normal 1,335 1,922 53
Plus (+) 1,469 2,115 38 Plus (+) 1,469 2,115 48
C
D
GMVC950453BX*
AMVC950453BX*
(Rise Range: 30 - 60°F)
A
B
D
GMVC950704CX*
AMVC950704CX*
Rise Range: 30 - 60°F)
A
B
C
GMVC950905DX*
AMVC950905DX*
(Rise Range: 30 - 60°F)
GMVC951155DX*
AMVC951155DX*
(Rise Range: 35 - 65°F)
AA
DD
BB
CC

Other manuals for Goodman GMVC950453BXAA