1
HUM
"C" WHITE TEXT ON BLUE BACKGROUND
W1
"1" WHITE TEXT ON BLACK BACKGROUND
C W1
DEHUM
C
"O" BLACK TEXT ON ORANGE BACKGROUND
2
THERMOSTAT HEADER
SEE NOTE 5
R W2 Y1G
C O
R
W1
"Y1" WHITE TEXT ON PURPLE BACKGROUND
W2
G
"DEHUM"; BLACK TEXT ON GRAY BACKGROUND
Y2
"R" BLACK TEXT ON RED BACKGROUND
1
1
"W2" WHITE TEXT ON BROWN BACKGROUND
Y2
W2
2
DEHUM
DE
G Y2
"G" WHITE TEXT ON GREEN BACKGROUND
O
2
R
"W1" BLACK TEXT ON WHITE BACKGROUND
O
Y1
"2" WHITE TEXT ON GRAY BACKGROUND
Y1
"Y2" BLACK TEXT ON YELLOW BACKGROUND
8
7
6 5
4
2 1
3
8
7 6
5 4 3
E
D
B
A
C
E
D
B
A
C
CONFIDENTIAL PROPERTY OF THE GOODMAN MANUFACTURING COMPANY, L.P. NOT TO BE DISCLOSED TO OTHERS, COPIED, OR USED FOR ANY PURPOSE
EXCEPT AS AUTHORIZED IN WRITING. MUST BE RETURNED UPON DEMAND, ON COMPLETION OF ORDER, OR OTHER PURPOSE FOR WHICH IT WAS LENT.
COMPONENTS AND MATERIALS SPECIFIED HEREIN WILL ALSO CONFORM TO THE APPLICABLE SECTION OF GOODMAN MSP 824.01 WORKMANSHIP
STANDARD FOR FIT, FEEL AND FINISH.
SPECIAL CHARACTERISTICS:
=
6SIGMA
=
CRITICAL CHARACTERISTIC
=
SIGNIFICANT CHARACTERISTIC
SC
CC
6s
PCB, CONTROL, FURANCE
DATE: 4-15-09
ENG: D WARREN
DWN BY: janderson
DO NOT SCALE DRAWING
PCBKF101
B
REV
CHK BY: D MASSEY
SHT 4 OF 6
THE GOODMAN MANUFACTURING
COMPANY, L.P.
TOLERANCES:
ANGLES ± 1.5°
.X : ± .1
.XX : ± .03
.XXX : ± .015
HOLE Ø : ± .005
TUBE CUT LG: ± .063
DRAWING TO BE INTERPRETED IN
ACCORDANCE WITH ASME Y14.100
DIMENSIONS ARE IN INCHES
UNLESS OTHERWISE NOTED
2 1
SILKSCREEN SHALL BE S1 FOR SWITCH BANK AND 1, 2, OR 3 FOR EACH SWITCH
* FACTORY DEFAULT
SILKSCREEN SHALL BE S2 FOR SWITCH BANK AND 1, 2, OR 3 FOR EACH SWITCH
* FACTORY DEFAULT
SILKSCREEN SHALL BE S3 FOR SWITCH BANK AND 1, 2, 3 OR 4 FOR EACH SWITCH
* FACTORY DEFAULT
SILKSCREEN SHALL BE S4 FOR SWITCH BANK AND 5, 6, 7 OR 8 FOR EACH SWITCH
* FACTORY DEFAULT
SILKSCREEN SHALL BE S5 FOR SWITCH BANK AND 9 OR 10 FOR EACH SWITCH
* FACTORY DEFAULT
UNUSED
SWITCH BANK S5
FUNCTION
10
VALUE
9
OFF*
ENABLE
DISABLE
DEHUM
ENABLE/DISABLE
ON
UNUSED
WIRING SCHEMATIC
R
Y1
1
2
4
8
C
N/C
N/C
6
12
2
7
15
9
3
10
1
14
5-11
13
8
1
5
HI
2
LO
3
4
3
3
4
1
G
DEHUM
Y2
O
W2
W1
XFMR
GAS VALVE
PS2
PS1
AUX
RLS
HL
VARIABLE SPEED
CIRCULATOR
INDUCER
EAC
HUM
IGN
LO
HI
DRAIN
SWITCH
GROUND
Z
CNTL
μP
COMM
μP
RS485
DUAL LED
DISPLAYS
COMM
STATUS LED
RJ11
DIPSWX
TX/RX
---
---
---
ON
ON
ON*
OFF*
OFF
1
STAGE DELAY
THERMOSTAT TYPE
HEAT OFF DELAY
FUNCTION
5 MINUTES
AUTO
---
TWO-STAGE
180 SECONDS
OFF
ON
120SECONDS
90 SECONDS
SINGLE-STAGE
150SECONDS
VALUE
2
3
4
OFF
OFF
ON*
ON*
OFF
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
SWITCH BANK S1
SWITCH BANK S2
FUNCTION
3
2
VALUE
1
---
---
---
ON*
PULL-DOWN
PULL-UP
TERMINATION
ON*
---
---
ON*
---
SWITCH BANK S2
FUNCTION
3
2
VALUE
1
---
---
---
ON*
PULL-DOWN
PULL-UP
TERMINATION
BUS BIAS
ON*
---
---
ON*
---
ON
OFF
OFF
OFF
OFF*
ON*
ON*
TAP D
TAP C
TAP B
SWITCH BANK S3
---
---
---
---
---
---
---
---
---
---
---
---
OFF
ON
OFF
OFF
4
3
2
VALUE
0%
TAP A
ON
OFF
10%
---
-10%
0%
FUNCTION
COOLING AIRFLOW
TAPS
AIRFLOW TRIM
1
OFF
OFF*
ON*
ON
---
---
---
TAP D
TAP C
TAP B
TAP A
ON
ON
OFF
OFF*
ON*
ON
OFF
OFF
OFF
OFF*
PROFILE 4
PROFILE 3
PROFILE 2
SWITCH BANK S4
---
---
---
---
---
---
---
---
---
---
---
---
OFF
OFF
8
7
6
VALUE
PROFILE 1
ON
OFF
---
FUNCTION
COOLING PROFILES
HEATING AIRFLOW TAPS
5
OFF*
ON
---
---
---
DETAIL A
VIEW FROM
SHEET 3