SS-GMVC95 www.goodmanmfg.com 7
product speciFications
gMVc95 airFlow speciFications (cont.)
Heating speeds
GMVC950453BXAA
(Rise Range: 30° - 60°F)
GMVC950704CXAA
(Rise Range: 30° - 60°F)
Cooling
Speed Tap
Adjust Tap
Low-Stage
CFM
1
High-Stage
CFM
1
Rise
(°F)
Cooling
Speed Tap
Adjust Tap
Low-Stage
CFM
1
High-Stage
CFM
1
Rise
(°F)
A
Minus (-) 505 720 56
A
Minus (-) 790 1125 54
Normal 560 800 51 Normal 875 1250 49
Plus (+) 615 880 46 Plus (+) 960 1375 44
B
Minus (-) 565 810 50
B
Minus (-) 850 1215 50
Normal 630 900 45 Normal 945 1350 45
Plus (+) 695 990 41 Plus (+) 1040 1485 41
C
Minus (-) 630 900 45
C
Minus (-) 915 1305 47
Normal 700 1000 40 Normal 1015 1450 42
Plus (+) 770 1100 37 Plus (+) 1115 1595 38
D
Minus (-) 695 990 41
D
Minus (-) 975 1395 44
Normal 770 1100 37 Normal 1085 1550 39
Plus (+) 845 1210 33 Plus (+) 1195 1705 36
¹ @ .1” to .5” W.C. ESP
GMVC950905DXAA
(Rise Range: 30° - 60°F)
GMVC951155DXAA
(Rise Range: 35° - 65°F)
Cooling
Speed Tap
Adjust Tap
Low-Stage
CFM
1
High-Stage
CFM
1
Rise
(°F)
Cooling
Speed Tap
Adjust Tap
Low-Stage
CFM
1
High-Stage
CFM
1
Rise
(°F)
A
Minus (-) 1010 1440 56
A
Minus (-) 1165 1665 61
Normal 1120 1600 51 Normal 1295 1850 55
Plus (+) 1230 1760 46 Plus (+) 1425 2035 50
B
Minus (-) 1070 1530 53
B
Minus (-) 1195 1710 59
Normal 1190 1700 48 Normal 1330 1900 53
Plus (+) 1310 1870 43 Plus (+) 1465 2090 48
C
Minus (-) 1135 1620 50
C
Minus (-) 1230 1755 58
Normal 1260 1800 45 Normal 1365 1950 52
Plus (+) 1385 1980 41 Plus (+) 1500 2145 47
D
Minus (-) 1195 1710 47
D
Minus (-) 1260 1800 56
Normal 1330 1900 43 Normal 1400 2000 51
Plus (+) 1465 2090 39 Plus (+) 1540 2200 46
¹ @ .1” to .5” W.C. ESP