Gossen MetraWatt PROFITEST INTRO - 14.3.2 Searching for Structure Elements

Gossen MetraWatt PROFITEST INTRO
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
40 GMC-I Messtechnik GmbH
Select a new object from a list.
Select the desired object from the list with the keys and
acknowledge with the key.
Depending upon the profile selected in the test instrument’s
SETUP menu (see section 4.5), the number of object types may
be limited, and the hierarchy may be laid out differently.
Enter a designation.
Enter a designation and then acknowledge it by pressing .
Note
Acknowledge the standard or adjusted parameters
shown below, because the created designation will oth-
erwise not be accepted and saved.
Set Electrical Circuit Parameters
For example, nominal current values must be entered here for the
selected electrical circuit. Measuring parameters which have been
accepted and saved in this way are subsequently accepted by
the current measuring menu automatically when the display is
switched from the structure view to measurement.
Note
Electrical circuit parameters changed during structure
creation are also retained for individual measurements
(measurement without saving data).
If you change the electrical circuit parameter specified by the
structure in the test instrument, a warning is displayed when
the change is saved (see error message on page 48).
14.3.2 Searching for Structure Elements
Regardless of the currently selected object, the search is started
at database.
Go to page 3/3 in the database menu.
After selecting text search ...
... and entering the desired text (only full matches are found – no
wild cards, case sensitive) ...
... the first match is displayed.
Further matches can be found by selecting the icon shown
at the right.
Scroll up
Scroll down
Acknowledge selection.
Select character
Select character
Accept characters
Delete characters.
Character selection:
Save object designation
A, a, 0, @
Select parameter
List of parameter settings
Acknowledge parameter selection
Acknowledge parameter setting
and return to page 1/3
Select parameter setting
in the database menu.
Scroll up
Scroll down
Acknowledge selection /
Display object
Menu selection page 3/3
change level
or ID number
Search for ID number
Search for text
Search for ID number or text.
Select character
Select character
Accept characters
Delete characters.
Character selection:
?
Save object designation
Continue searching