18
Maintenance
1.
Clean the cooking tray after every use, clean the tube when
needed and only after it has cooled down.
2.
The stainless steel cooking tray can easily be cleaned by hand.
3.
It is recommended that you clean the inside of the glass tube
occasionally to prevent build-up of grease or food matter, which
can affect the avor of food.
4.
Keep surfaces of tube and reectors clean with glass cleaner or
mild soap.
5.
If the GoSun cooking tray becomes deformed after extensive use
and becomes noticeably harder to insert into the tube, it can be
remedied by squeezing the tray by hand.
6.
If the indicator light turns off, but you still have 12v power
available, check the fuse located inside the DC cigarette plug.
Replace if needed with a standard 20A glass fuse.
7.
If the evacuated tube breaks, it can be removed and replaced by
following the Tube Removal section on the previous page. The
GoSun Fusion uses the best evacuated tubes available on the
market, however if they are damaged, a barium layer will oxidize
and a white lm will appear on the inside of the outer tube,
indicating that the tube should be replaced.